What are the PCB panelization rules?

What are the PCB panelization rules?

日本語

Such orders can directly be placed on Seeed Fusion Service. 

 A.  There is no extra cost for identical design panelization.  


ie. If you choose "Different Designs =  1" that means there is only one design in your PCB Gerber file. So if you want to separate multiple boards with V-cut or milled slots, please make sure each sub-board is the same and less than 40 pieces sub-boards per panel, otherwise, there may be extra processing charges.



Tips:  a) Draw the v-cut line in the outline layer (GKO/GML), e.g. put in layer 20 or 46 in Eagle.

   b) If possible make a note beside the v-cut line as the following picture shows.

    

 If you want to use v-cut, please following those rules:1) The panel must fit the selected V-cut equipment. Confirm the current panel-size limits before panelizing.


2) Sub-board dimensions must provide sufficient support and remaining material. Confirm the minimum dimensions during file review.

3) V-cut lines must be straight.

4) V-cut lines must run from edge to edge without jump cuts.

5) Confirm the current V-cut line width and centerline-to-copper clearance for the selected process.

6) V-cut is not suitable for every board thickness. Confirm the minimum thickness for the selected production route.



 B. Different PCB panelization.


Tips: a) Put all designs in one Gerber file.

     b) Make sure the cut lines (slots) are in outline layer (GKO/GML), and the complete board outline should go all round the edge of the boards.


  c) Choose "Panelized PCBs" option, ie. 2 panelization= 2 designs, Maximum is 9 designs.

         

Panelization allows you to put sub-boards on one panel. 

For example, we have three PCBs need to be made on one panel.


This is an INCORRECT EXAMPLE, Please DO NOT draw the outline like the pictures below. 

Problem: There are 4 outlines, we have no idea which outlines we should follow.




Problem: The width of connections is too small and too long.

Problem: The panel dimensions do not meet the current production limits.V-cut panel width and length must be checked against the current production limits. The earlier 55 mm and 70 mm values are no longer used as standalone rules.


Problem: The v-cutting line should be straight and edge to edge.



CORRECT EXAMPLE

Panelized '1'


 Panelized '1'

Add margin to hold the sub-boards, the width of margin should be more than 3mm.


 Panelized '2'

Add connections and stamp holes to separate the board. 


Panelized '3'

Add slots to separate the board.


Panelized '1'.

If you don't want to pay extra money for the panelize fee. You can make the outline like this and cut the board by yourself.




C. No panelization.

 Tips:  a) Please make sure the complete board outline should go all round the edge of the boards.

      b) Use silkscreen to separate the board, No cut line in Outline layer (GKO/GML), please see the following picture

           c) You will get 1 complete board WITHOUT any cutting no matter you put different designs or same design here.




Content updated: 2026-11-20.